Fibershield-E - Heat transmission

Fibershield-E 
Heat transmission



The economical textile fire protection closure with the highest level of standardisation


Protection targets




Integrity with
limitation of the
heat transmission

Schutzziel EW - Begrenzung des Strahlungsdurchtritts
Classifikation

EW 90

Fabric Heliotex EW 90
Test reports

UB III/B-08-012

UB III/B-06-005



Description of the Fibershield-E system


  • high level of standardisation which leads to an economic sealing system with a maximum width of up to 6 m and a drop length of up to 8 m or a width up to 7 m and a drop length of up to 5 m
  • drive system “Gravigen” as a standard - closing without auxiliary power, no fire-rated cables necessary
  • high number of cycles of the motors of 10.000 cycles
  • different protection targets E, EW, EI (with water) by using different types of fabrics
  • side guides with buttons
  • large fire protection closures of min. class C 1 according to DIN EN 13501-2
  • optional with safety edge
  • optional with self-levelling bottom bar
System width Drop length

Fabric
System width Drop length
(mm)
h
(mm)
Heliotex EW 90 > 1,1 m < 4 m ≤ 5 m 200 220
Heliotex EW 90 > 1,1 m < 5 m ≤ 4 m 200 220
Heliotex EW 90 > 1,1 m < 6 m ≤ 3 m 200 220


Range of casings



Installation to the ceiling   Installation to the wall   With self-levelling bottom bar
Installation to the ceiling   Installation to the wall   With self-levelling bottom bar



Bottom bar



Standard design Self-levelling bottom bar



Installation of the side guide


   
Type 80 K   Type 80 KB   Type 80 KN



Alternatives for the installation


     
Installation of the casing to the wall, front site run   Installation of the casing to teh wass, false ceiling is attached to the casing on one side, front site run   Installation of the casing directly to the ceiling   Installation of the casing directly to the ceiling, false ceiling is attached to the casing on both sides

Installation of the casing to the ceiling by using hangers Installation of the casing to the ceiling by using hangers, 
false ceiling is attached to the the casing on both sides

Control units for fire protection closures

Control units for single closures:

Control units for multiple closures: