Fibershield-P - Heat transmission

Fibershield-P Heat transmission



The Premium textile fire protection closure to match the highest demands and to achieve large dimensions




Protection target



Integrity with limitation 
of the heat transmission
Integrity with limitation of the heat transmission
Classification

EW 90
EW 120

Fabric

Heliotex EW 90
Heliotex EW 120

Test reports UB III/B-08-012
UB III/B-07-003
UB 3.3 / 10-035-1
UB 3.3 / 11-009-1

 


Description of the Fibershield-P system

  • Approval classification E90, 10.000 cycles
  • Scope of approval 1000 mm x 2000 mm – 10.000 mm x 7.600 mm
  • Made out of one piece up to a width of 30 m and for a large drop length (see table)
  • Highest variability for the construction and the design
  • Drive system "Gravigen" as a standard - that is closing without auxiliary power, no fire-rated cables necessary
  • High number of cycles of the motor of 10.000 cycles
  • Only one drive system is necessary - therefore a reduced effort to the installation
  • Different protection targets E, EW, EI (with water) by using different types of fabrics
  • Large widths as well as the self levelling bottom bar (for the standard casing)
  • The safety edge in combination with the self levelling bottom bar is possible as an option
  • Continuing lateral fixing of the fabric by using the side guides with steel rod for large drop length, high pressures, high tightness and gentle closing
  • Warping free bottom bars even in case of temperature influence
  • Large fire protection closures min. class C1 regarding DIN EN 13501-2


Fixed bearing



 

Fabric System width Drop length d
(mm)
h
(mm)
Heliotex EW 90 / 120
>0,8 < 4 m ≤ 2 m 190 250
Heliotex EW 90 / 120 >0,8 < 4 m ≤ 7,5 m 235 290

The dimensions of the casing for drop length of 9 - 12 m depend on the requested coil.


Floating bearing



 

Fabric System width Drop length d
(mm)
h
(mm)
Heliotex EW 90 / 120 > 4 m - ≤ 12 m ≤ 2 m
190 250
Heliotex EW 90 / 120 > 4 m - ≤ 12 m ≤ 6 m 235 290

The dimension of the casing for drop lengths of 9-12 m depends on the requested coil.



Range of casings


Standard  fixed bearing   Standard  floating bearing   Range of special constructions  
Standard fixed bearing   Standard floating bearing   Range of special constructions  



Bottom bars



Standard with small widths

Type 4,6   heavy, Type 9.6   small, Type 5,61
Type 4,6   heavy, Type 9.6   small, Type 5,61


Standard with large widths

<center>Type 3,84 F  self levelling bottom bar without safety edge</center>   <center>Type 3,84 FK  self levelling - optional with safety edge</center>   <center>  self levelling bottom bar without safety edge, under ceiling</center>
Type 3,84 F self levelling bottom bar without safety edge
 
Type 3,84 FK self levelling - optional with safety edge
 
self levelling bottom bar without safety edge, under ceiling



Range of side guides



Continuous fabric
clamping due to rod
guiding for high
pressures and high
tightness
Durchgehende Gewebeeinspannung
Type Drop  length Surface
80 E ≤ 3,5 m ≤ 18 m2
105 E 
≤ 6 m ≤ 50 m2
105 V 
≤ 6 m ≤ 70 m2
160 E 
≤ 9 m ≤ 120 m2

 

 

     
Type 105 E 
installation to the wall
 
Type 105 E 
installation in the embrasure
 
Type 105 E
installation in the niche
 
Type 105 V 
installation to the wall

     
Type 105 V 
installation in the embrasure
 
Type 105 V 
installation in the niche
 
Type 80 E
installation to the wall
 
Type 80 E
installation in the embrasure

     
Type 80 E
installation in the niche
 
Type 140 E
installation to the wall
 
Type 140 E
installation in the embrasure
 
Type 140 E
installation in the niche



Alternatives for the installation


     
Installation of the casing to the wall, front site run   Installation of the casing to the wall, rear site run   Installation of the casing to the wall, false ceiling is attached to the casing on one side, front site run   Installation of the casing to the wall, false ceiling is attached to the casing on one side, rear site run

     
Installation of the casing directly to the ceiling   Installation of the casing directly to the ceiling, false ceiling is attached to the casing on both sides   Installation of the casing to the ceiling by using hangers   Installation of the casing to the ceiling by using hangers, false ceiling is attached to the casing on both sides

Control units for fire protection closures

Control units for single closures:

Control units for multiple closures: