CONTACT

Call: +971 5 448 448 58
Fax: +971 4 355 8090
E-mailThis email address is being protected from spambots. You need JavaScript enabled to view it.

Call: +971 5 448 448 58
Fax: +971 4 355 8090
E-mailThis email address is being protected from spambots. You need JavaScript enabled to view it.

Fibershield-P - Sprinkler protection

Fibershield-P Sprinkler protection



The Premium textile fire protection closure to match highest demands and to achieve large dimensions




Protection target



Instulation with intesified 
sprinkler protection in 
case of fire
Instulation with intesified sprinkler protection in case of fire
Classification

EI 120
EI 180

Fabric

Protex 1100 B1
Protex 1100.1 A2

Test reports UB III/B-05-006 
UB III/08-016
UB III/B-07-10-2
Water irrigation



Description of the Fibershield-P system

  • Approval classification E90, 10.000 cycles
  • Scope of approval 1000 mm x 2000 mm - 10.000 mm x 7.600 mm
  • Made out of one piece up to a width of 30 m and for a large drop length (see table)
  • Highest variability for the construction and the design
  • Drive system "Gravigen" as a standard - that is closing without auxiliary power, no fire-rated cables necessary
  • High number of cycles of the motor of 10.000 cycles
  • Only one drive system is necessary - therefore a reduced effort to the installation
  • Different protection targets E, EW, EI (with water) by using different types of fabrics
  • Large widths as well as the self levelling bottom bar (for the standard casing)
  • The safety edge in combination with the self levelling bottom bar is possible as an option
  • Continuing lateral fixing of the fabric by using the side guides with steel rod for large drop length, high pressures, high tightness and gentle closing
  • Warping free bottom bars even in case of temperature influence
  • Large fire protection closures min. class C1 regarding DIN EN 13501-2

 
 

Fixed bearing



 

Fabric Length of the system Drop length d
(mm)
h
(mm)
Protex 1100.1 A2 > 0,8 m - ≤ 1,4 m ≤ 3,5 m 190 250
Protex 1100.1 A2 > 1,4 m - ≤ 4 m ≤ 3,5 m 190 200
Protex 1100.1 A2 >0,8 < 4 m > 3,5 m - ≤ 6 m 190 250
Protex 1100.1 A2 >0,8 < 4 m > 6 m - ≤ 9 m 235 290

The dimensions of the casing for drop lengths of 9-12 m depend on the requested coil.


Floating bearing



 

Fabric Length of the system Drop length d
(mm)
h
(mm)
Protex 1100.1 A2 > 4 m - ≤ 22 m ≤ 3,5 m 190 200
Protex 1100.1 A2 > 4 m - ≤ 22 m > 3,5 m - ≤ 6 m 190 250
Protex 1100.1 A2 > 4 m - ≤ 20 m > 6 m - ≤ 9 m 235 290

The dimensions of the casing for drop lengths of 9-12 m depend on the requested coil.



Range of casings


Standard  fixed bearing   Standard  floating bearing   Range of special constructions  
Standard fixed bearing   Standard floating bearing   Range of special constructions  



Bottom bars



Standard with small widths

Type 4,6   heavy, Type 9.6   small, Type 5,61
Type 4,6   heavy, Type 9.6   small, Type 5,61


Standard with large widths

<center>Type 3,84 F  self levelling bottom bar without safety edge</center>   <center>Type 3,84 FK  self levelling - optional with safety edge</center>   <center>  self levelling bottom bar without safety edge, under ceiling</center>
Type 3,84 F self levelling bottom bar without safety edge
 
Type 3,84 FK self levelling - optional with safety edge
 
self levelling bottom bar without safety edge, under ceiling



Range of side guides



Continuous fabric
clamping due to rod
guiding for high
pressures and high
tightness
Durchgehende Gewebeeinspannung
Type Drop  length Surface
80 E ≤ 3,5 m ≤ 18 m2
105 E 
≤ 6 m ≤ 50 m2
105 V 
≤ 6 m ≤ 70 m2
160 E 
≤ 9 m ≤ 120 m2

 

 

     
Type 105 E 
installation to the wall
 
Type 105 E 
installation in the embrasure
 
Type 105 E
installation in the niche
 
Type 105 V 
installation to the wall

     
Type 105 V 
installation in the embrasure
 
Type 105 V 
installation in the niche
 
Type 80 E
installation to the wall
 
Type 80 E
installation in the embrasure

     
Type 80 E
installation in the niche
 
Type 140 E
installation to the wall
 
Type 140 E
installation in the embrasure
 
Type 140 E
installation in the niche



Alternatives for the installation


     
Installation of the casing to the wall, front site run   Installation of the casing to the wall, rear site run   Installation of the casing to the wall, false ceiling is attached to the casing on one side, front site run   Installation of the casing to the wall, false ceiling is attached to the casing on one side, rear site run

     
Installation of the casing directly to the ceiling   Installation of the casing directly to the ceiling, false ceiling is attached to the casing on both sides   Installation of the casing to the ceiling by using hangers   Installation of the casing to the ceiling by using hangers, false ceiling is attached to the casing on both sides

Control units for fire protection closures

Control units for single closures:

Control units for multiple closures: