Smoke barrier Apericoil

Smoke barrier Apericoil


The self-opening smoke barrier at a temperature influence > 350°C

Tight up to 350°C Heat flow at a temperature of 350°C

System description

  • Patented fabric “Aperitex 400”
  • Prefabricated single modules will be strung together to a complete barrier up to an arbitrary
  • Drop lengths up to 4 m
  • Designed for the time-class and temperature load DL = 300°C
  • Drive-unit “Gravigen” as standard; that means closing without auxiliary energy; fire-resistant cables are not necessary
  • Connected bottom bars across all modules
  • Alternatively with lateral side guides

 

Customer benefit

  • The discrepancy, to positively dissipate the smoke with temperatures from 300°C to 400°C and to avoid that higher temperatures have influence on the building structure
  • The Aperitex-fabric opens at temperatures from 380°C and stays 80% open at 500°C (the rest are remaining lattice structures)
  • The lattice structure has a heat resistance of about over 600°C for 2 hours so that the system will not crash under this load
  • The constructional designs (casing, side guides, bottom bar) correspond to the proven system Moducoil
  • The classification according to ISO 21027-1 is the class DL 120, that means 300°C for 120 minutes
  • The fabric is transparent therefore good observe possibilities


Dimensions


   
   

 

a = side guide
b = joint without side guide


Single module up to 6m system width

Drop length t1 
(mm)
h1
(mm)
t2
(mm)
h1
(mm)
≤4,5 m 250 150 150 150
>4,5 m - ≤8,5 m 320 180 180 180


Selection of casings


Single smoke barrier wall   Modular smoke barrier wall (standard)   Single smoke barrier ceiling
Single smoke barrier wall   Modular smoke barrier wall (standard)   Single smoke barrier ceiling

Modular smoke barrier ceiling Smoke barrier with self-levelling bottom bar

Bottom bar


Standard

     
   



Selection of side guides


       
 Wall Embrasure Niche

 



Penetrability

 Graphic illustration of the smoke penetrability depending on the temperature

Graphic illustration of the smoke penetrability depending on the temperature

 



CE classification




Patented tubular motor with
Gravity Fail technology





Aperitex 400: 
the intact fabric structure restrains the smoke up to 350°C, Fabric opens up at 350°C and lets the smoke pass 

 
Label ISO 21927-1 Stöbich
system Apericoil
Automatic smoke barrier Type ASB 1 / ASB 3
closing without auxiliary energy
Temperature class DL 120
(300°C / 120 min.)
Closing time
(depending on the drive)

0,15 m/s
e.g. drop length 9 m = 60 s in fire alarm position

Joint casing (a-f) 0 mm
Joint edges (g) embrasure

g = 0 mm with side guide (SG) 
g = 20 mm + 20 mm without SG

Joint connection (h)

17 mm (standard ceiling installation)
0 mm (standard wall installation

Max. penetrability of the 
smoke barrier fabric 
(max. 25m3/m2/h)
< 1m3 /m2 /h
Free surface casing Casing length x Gap casing = L x 0 = 0 mm2
Free surface edges 
= D x Gap edges
Free surface joint 
= D x Gap joint x Number of joints

D=Drop length of the smoke barrier

 
Connection


Casing


Edges

 

Control units for smoke barriers/smoke barrier

Control units for single smoke barriers/smoke barrier:

Control units for multiple smoke barriers/smoke barrier: